Why Generator Emissions Matter for Construction ESG Reporting
Environmental, Social and Governance (ESG) reporting has moved from a voluntary exercise to a mainstream requirement. This applies across infrastructure, rail, utilities and public sector construction in the UK
Scope 1 emissions are direct emissions from sources a contractor owns or controls — including fuel combustion from generators, plant and vehicles on site.
Despite this, generator emissions are frequently underreported, inconsistently measured or simply omitted from project-level carbon accounts. As ESG frameworks tighten and client scrutiny increases, this is becoming an increasingly significant gap.
Understanding Scope 1, 2 and 3 Emissions in Construction
Before addressing generator emissions specifically, it helps to understand how construction carbon is categorised under the GHG Protocol — the internationally recognised framework for greenhouse gas accounting.
Scope 1 — Direct emissions. Emissions from sources directly owned or controlled by the contractor. This includes diesel generators, site plant, company vehicles and any other combustion equipment operated on site. Generator fuel consumption is a Scope 1 emission.
Scope 2 — Indirect energy emissions. Emissions associated with purchased electricity or heat. Where a site draws from the grid, the carbon intensity of that electricity supply is a Scope 2 emission.
Scope 3 — Value chain emissions. All other indirect emissions associated with the contractor’s activities, including materials supply, subcontractor activities, employee travel and waste disposal.
For temporary power, the primary reporting category is Scope 1. Every litre of diesel burned in a generator on site produces a direct, measurable carbon emission that must be accounted for under accurate ESG reporting.
How to Calculate Generator Emissions for ESG Reporting
Calculating Scope 1 emissions from diesel generators is straightforward in principle. The standard approach uses published emissions factors from the UK Government’s DEFRA Greenhouse Gas Reporting guidelines.
Standard mineral diesel emissions factor: approximately 2.68 kg CO₂e per litre
To calculate total generator emissions for a project:
- Record total fuel consumption in litres over the reporting period
- Multiply by the DEFRA emissions factor for the fuel type used
- Report the result in kg or tonnes of CO₂ equivalent
Example: A generator consuming 20 litres per hour over a 10-hour day, running seven days a week for 26 weeks produces approximately 36,400 litres of diesel consumption. At 2.68 kg CO₂e per litre, this equates to approximately 98 tonnes of CO₂e — a significant figure for a single piece of site equipment.
For HVO fuel, the emissions factor is dramatically lower — typically 0.19 to 0.54 kg CO₂e per litre depending on feedstock and supplier certification. Contractors using HVO should obtain a sustainability certificate from their fuel supplier confirming the applicable emissions factor.
Why Generator Emissions Are Frequently Underreported
Several practical factors lead to generator emissions being inaccurately reported on construction projects:
Fuel records are incomplete. Fuel deliveries to site are not always systematically recorded against specific equipment. Where multiple generators or plant items share a fuel supply, apportioning consumption accurately is challenging.
Runtime is not monitored. Without active monitoring, contractors rely on estimates of generator runtime rather than actual measured data. This typically results in either under or overestimation.
Subcontractor emissions are excluded. Where generators are operated by subcontractors, their fuel consumption may fall outside the principal contractor’s Scope 1 reporting boundary — creating a gap in the project carbon account.
Default factors are applied incorrectly. Using standard diesel emissions factors for fuel that is actually HVO, or vice versa, produces inaccurate reported figures.
hybrid systems with built-in monitoring systems address several of these challenges directly by providing accurate, real-time fuel consumption and runtime data.
How Hybrid units Strengthen ESG Reporting
SolGen hybrid units contribute to ESG performance in two distinct ways — by reducing actual emissions and by improving the quality of emissions data available for reporting.
Reducing actual emissions. By prioritising solar and battery power over diesel generation, SolGen units prioritise solar and battery power over diesel generation, so the generator runs far less than in a diesel-only system.. Fewer engine hours means less fuel consumed and proportionally fewer Scope 1 emissions. This is a real, measurable reduction — not an accounting adjustment.
Improving data quality. SolGen’s monitoring portal provides continuous real-time data on fuel consumption, generator runtime, solar generation and battery performance. This data can be exported over any chosen timeframe and provides the accurate fuel consumption figures needed for compliant ESG reporting.
Evidencing reduction against baseline. The monitoring system compares actual performance against a diesel-only baseline, providing a clear narrative of emissions avoided. This is increasingly what clients, auditors and ESG frameworks require — not just a reported figure, but evidence of what was done to reduce it.
ESG Frameworks Relevant to UK Construction
Several frameworks and standards are relevant to how UK construction contractors approach carbon reporting:
PAS 2080 — Carbon Management in Infrastructure. Published by BSI, PAS 2080 provides a framework for managing carbon across the lifecycle of infrastructure assets. It is increasingly specified by major infrastructure clients and requires contractors to set and evidence carbon reduction targets.
ISO 14064 — Greenhouse Gas Accounting. The international standard for quantifying and reporting greenhouse gas emissions. ISO 14064 certification demonstrates rigorous carbon accounting practice.
Science Based Targets initiative (SBTi). A growing number of Tier 1 contractors have committed to science-based emissions reduction targets aligned with the Paris Agreement. These commitments require measurable, evidenced reductions across Scope 1, 2 and 3 emissions.
GHG Protocol Corporate Standard. The most widely used international framework for corporate greenhouse gas accounting, forming the basis of most ESG reporting methodologies in use across UK construction.
SECR — Streamlined Energy and Carbon Reporting. A UK government requirement for large companies to report energy use and carbon emissions in their annual reports. For qualifying contractors, generator fuel consumption must be included in SECR disclosures.
What Clients Are Now Requiring from Contractors
The shift in client expectations around ESG is accelerating. Across public sector, rail, utilities and major private infrastructure, contractors are increasingly required to:
- Submit pre-contract carbon management plans detailing how emissions will be measured and reduced
- Report project-level Scope 1 emissions at regular intervals during delivery
- Demonstrate use of low-emission plant and equipment including generators
- Evidence actual emissions reductions against an agreed baseline
- Provide fuel consumption records and monitoring data to support reported figures
For temporary power specifically, clients are moving beyond simply asking whether a generator is Stage V compliant. The question is increasingly what the total fuel consumption and runtime will be — and what active steps are being taken to minimise it.
Hybrid systems with monitoring portals provide the data infrastructure to answer these questions accurately and efficiently.
Practical Steps for Improving Generator ESG Performance
For contractors looking to strengthen their ESG position on temporary power, the following steps represent a practical starting point:
1. Establish a fuel consumption baseline. Before you can reduce emissions, you need to know what you are currently producing. Implement fuel recording across all generator assets on site.
2. Specify hybrid solar power on eligible projects. Any project with a duration of four weeks or more, variable load demand or urban location is a candidate for hybrid solar power. Build this into your temporary power procurement process.
3. Specify HVO fuel as standard. Hybrid systems reduce generator fuel consumption, with the saving depending on load and site conditions.”
4. Use monitoring data for reporting. Insist on real-time monitoring from your temporary power supplier. Accurate fuel and runtime data is the foundation of credible ESG reporting.
5. Report against a baseline. Document the diesel-only baseline your hybrid system is replacing. Reporting emissions avoided — not just emissions produced — tells a more complete and compelling sustainability story.
6. Include subcontractor emissions. Ensure your ESG reporting boundary includes temporary power operated by subcontractors, not just directly operated assets.
Summary — ESG and Generator Emissions Key Points
- Generator diesel combustion is a Scope 1 emission and must be included in ESG reporting
- The DEFRA emissions factor for standard diesel is approximately 2.68 kg CO₂e per litre
- HVO fuel reduces the lifecycle emissions factor by up to 90%depending on the feedstock
- Hybrid units reduce total fuel consumption by up to 90% depending on the feedstock compared to diesel-only systems
- Real-time monitoring provides the accurate data needed for compliant, evidenced ESG reporting
- Client requirements for carbon evidence are increasing rapidly across UK infrastructure
To discuss how SolGen hybrid systems can support your ESG reporting and carbon reduction strategy, contact our Technical Sales team.